Revista Digital de Postgrado ; 1(1): 16-27, jun. 2012. tab, graf
Article in Spanish | LILACS, LIVECS | ID: biblio-1096348

ABSTRACT

Para determinar fracción espirada final de sevoflurane al retirar tubo orotraqueal y máscara laríngea sin compli-caciones en pacientes pediátricos, se elaboró estudio obser-vacional de tipo descriptivo y, transversal, seleccionando un total de 40 pacientes de pediatría quirúrgica (Hospital Universitario de Caracas) para cirugías urológicas y her-nioplastias, distribuidos en grupo T (tubo orotraqueal) y grupo M (máscara laríngea). Premedicados con Midazo-lam recibieron anestesia inhalatoria y bloqueo regional. Mantenimiento: O2/aire 50/50. Concluida la cirugía se retiró dispositivo según parámetros hemodinámicos, clí-nicos y ventilatorios. Hubo diferencias estadísticamente significativas entre ambos dispositivos para presión arte-rial sistólica y diastólica, tiempo retiro del dispositivo de la vía aérea ­ salida del quirófano (TR) y complicaciones, no para fracción espirada. Se concluyó que para retiro de máscara laríngea y tubo orotraqueal, la fracción espirada final de sevoflurane fue de 0,66 y 0,87 respectivamente, siendo la máscara laríngea el dispositivo más recomenda-do por menor TR y menor número de complicaciones (AU)


To determine end-tidal sevoflurane fraction by removing endotracheal tube and laryngeal mask in pediatric patients without complications was developed observational and descriptive, transversal, selecting a total of 40 surgical pedia-tric patients (Hospital Universitario de Caracas) for surgery hernioplasties urological and distributed in group T (endo-tracheal tube) and group M (laryngeal mask). Premedicated with midazolam received inhalation anesthesia and regional blockade. Maintenance: O2/aire 50/50. Completed surgery withdrew device according to hemodynamic parameters, clinical and ventilator. Significant differences between the two devices for systolic and diastolic blood pressure, while removing the device from the air - out of the operating room (TR), and complications, not fractional exhaled. It was con-cluded that removal of laryngeal mask and endotracheal tube, the end-tidal sevoflurane fraction was 0.66 and 0.87 respectively, and the laryngeal mask device smaller than recommended by TR and fewer complications (AU)


Subject(s)
Humans , Male , Female , Child, Preschool , Midazolam/pharmacology , Laryngeal Masks , Sevoflurane/pharmacology , Intubation, Intratracheal/adverse effects , Blood Pressure , Child, Preschool , Laryngismus , Heart Rate
SELECTION OF CITATIONS
SEARCH DETAIL